GRAY COAT
Gray Coat
GRAY COAT is a single component liquid applied, water based, waterproofing membrane. It uniquely combines the features of a sealer and an elastomeric waterproofing membrane. Its high solid and low viscosity make this material effective for waterproofing and sealing concrete, asphalt, wood, metal and other common surfaces.
GRAY COAT is easy to apply and when cured, it provides a tough, highly flexible seamless membrane, with excellent adhesion to most substrates. When fully cured, it is highly resistant to water and salts. |
PDF Downloads |
Usage
GRAY COAT has been specifically formulated as a waterproofing membrane. It may be applied to all common surfaces and suitable for both new construction and restoration.
Typical applications include below grade foundation wall waterproofing, horizontal, sloped, and vertical surfaces such as:
Typical applications include below grade foundation wall waterproofing, horizontal, sloped, and vertical surfaces such as:
- Below grade walls
- Mechanical rooms
- Between slabs
- Shower rooms
- Planters
- Reflection pools
- Podium decks
- Balconies
- Reservoirs and tanks
- Asphalt, tiles etc.
Surface Preparation
Substrate should be clean, sound, dry, and free of any contaminants which may affect the membrane during or after cure. The presence of small amount of moisture in the substrate (such as in concrete, not fully cured) will not be detrimental to the performance of GRAY COAT.
Application
- GRAY COAT may be sprayed, brushed, or applied with a trowel.
Curing & Drying
Allow the material to dry at air and surface temperature of 2°C (35°F) or higher. Curing times will be affected by relative humidity temperature and air flow. The following times are given for average conditions and standard thickness. Actual times may differ depending on specific conditions present on job at time of application.
It is recommended that GRAY COAT be allowed to air dry to a tack free, gray film before application of specified insulation, protection board or other cover.
- Track free film 2 to 5 hours
- 60% cure 7 days
- 90% cure 28 days
It is recommended that GRAY COAT be allowed to air dry to a tack free, gray film before application of specified insulation, protection board or other cover.
Clean-up
Uncured material can be cleaned using light soap and water. Cured material is best removed by xylol or by mechanical means.
Packaging
Type | Available Size | Code |
---|---|---|
Gray Coat can | 1 US gallon can (8.8 lbs / 4 litres – 4 kg) | GCC-001 |
Gray Coat pail | 5 US gallon pail (44 lbs / 20 litres – 20 kg) | GCC-010 |
Storage
- Keep containers tightly sealed. Store in temperature range of 2°C to 30°C (35°F to 95°F).
- KEEP FROM FREEZING.
- SHELF LIFE: Indefinite in original sealed properly stored container.